<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Zemic B9D load cell Archives - Load Cell Express</title>
	<atom:link href="https://loadcellexpress.com/product-tag/zemic-b9d-load-cell/feed/" rel="self" type="application/rss+xml" />
	<link>https://loadcellexpress.com/product-tag/zemic-b9d-load-cell/</link>
	<description>Load Cell Express</description>
	<lastBuildDate>Tue, 04 Aug 2026 02:33:56 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>
	<item>
		<title>B9D load cell</title>
		<link>https://loadcellexpress.com/shop/tank-beam-double-ended/b9d-load-cell/</link>
		
		<dc:creator><![CDATA[romans]]></dc:creator>
		<pubDate>Tue, 04 Aug 2026 02:33:53 +0000</pubDate>
				<guid isPermaLink="false">https://loadcellexpress.com/?post_type=product&#038;p=4719</guid>

					<description><![CDATA[<h1 class="lede"><strong>B9D load cell - </strong>B9D Stainless Steel Dual Shear Beam Load Cell</h1>
<h2 class="lede"><strong>B9D load cell</strong></h2>
<p>is a high-accuracy, stainless steel dual shear beam load cell for truck scales, vehicle testing facilities, track scales, tank scales, and other heavy-duty electronic weighing systems. Adhesive potting helps protect the sensor against oil, water, corrosive gases, and demanding industrial environments.</p>
<ul class="trust-list" aria-label="Product highlights">
<li>1,000–75,000 lb capacities</li>
<li>IP67 protection</li>
<li>3.0 mV/V output</li>
<li>6 m shielded cable</li>
</ul>
<h2 id="why-b9d">Why choose the Zemic B9D?</h2>
<p class="section-intro">The B9D combines a stainless steel body with an adhesive-potted sensor design for weighing in wet, oily or corrosive industrial settings. It is a dual shear beam load cell with 3.0 ± 0.008 mV/V output, IP67 protection and rated capacities documented from 1 to 75 Klb.</p>
<div class="feature-grid">
<article class="feature">
<h3>Built for harsh environments</h3>
<p>Adhesive potting and IP67 protection help resist oil, water, corrosive gases and normal outdoor exposure.</p>
</article>
<article class="feature">
<h3>Heavy-scale versatility</h3>
<p>Use it in electronic truck scales, track scales, tank scales, vehicle testing facilities and other weighing systems.</p>
</article>
<article class="feature">
<h3>Broad capacity range</h3>
<p>Thirteen purchasable model options cover capacities from 1,000 lb through 75,000 lb.</p>
</article>
</div>
<p>&#160;</p>
<p class="source-line">Specifications verified against the supplied <a title="Zemic B9D manufacturer datasheet" href="https://loadcellexpress.com/wp-content/uploads/2026/08/B9D.pdf" target="_blank" rel="noopener">Zemic B9D manufacturer datasheet</a>. Page reviewed July 27, 2026.</p>
<p>The post <a href="https://loadcellexpress.com/shop/tank-beam-double-ended/b9d-load-cell/">B9D load cell</a> appeared first on <a href="https://loadcellexpress.com">Load Cell Express</a>.</p>
]]></description>
										<content:encoded><![CDATA[<section class="section" aria-labelledby="models-prices">
<h2 id="models-prices">B9D models, capacities and prices</h2>
<p class="section-intro">Select capacity based on the load per cell, required resolution, dead load, dynamic loading and the safety margin specified by the scale designer.</p>
<div class="table-wrap">
<table class="price-table">
<thead>
<tr>
<th scope="col">Model / SKU</th>
<th scope="col">Rated capacity</th>
<th scope="col">Price (USD)</th>
</tr>
</thead>
<tbody>
<tr>
<td>B9D-N3-1K-6B</td>
<td>1,000 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-1.5K-6B</td>
<td>1,500 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-2K-6B</td>
<td>2,000 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-2.5K-6B</td>
<td>2,500 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-3K-6B</td>
<td>3,000 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-5K-6B</td>
<td>5,000 lb</td>
<td>$450.00</td>
</tr>
<tr>
<td>B9D-N3-10K-6B</td>
<td>10,000 lb</td>
<td>$610.00</td>
</tr>
<tr>
<td>B9D-N3-15K-6B</td>
<td>15,000 lb</td>
<td>$610.00</td>
</tr>
<tr>
<td>B9D-N3-20K-6B</td>
<td>20,000 lb</td>
<td>$610.00</td>
</tr>
<tr>
<td>B9D-N3-25K-6B</td>
<td>25,000 lb</td>
<td>$610.00</td>
</tr>
<tr>
<td>B9D-N3-35K-6B</td>
<td>35,000 lb</td>
<td>$610.00</td>
</tr>
<tr>
<td>B9D-N3-50K-6B</td>
<td>50,000 lb</td>
<td>$1,220.00</td>
</tr>
<tr>
<td>B9D-N3-75K-6B</td>
<td>75,000 lb</td>
<td>$1,220.00</td>
</tr>
</tbody>
</table>
</div>
<p class="fine-print">Prices are provided in USD and should be synchronized with the live store or product feed before publication. Availability was not supplied and is therefore not claimed on this page.</p>
</section>
<section id="specifications" class="section" aria-labelledby="spec-heading">
<h2 id="spec-heading">B9D technical specifications</h2>
<div class="spec-grid">
<div class="table-wrap">
<table>
<tbody>
<tr>
<th scope="row">Load cell type</th>
<td>Dual shear beam</td>
</tr>
<tr>
<th scope="row">Material</th>
<td>Stainless steel</td>
</tr>
<tr>
<th scope="row">Ingress protection</th>
<td>IP67</td>
</tr>
<tr>
<th scope="row">Rated capacities</th>
<td>1 / 1.5 / 2 / 2.5 / 4 / 5 / 10 / 15 / 20 / 25 / 35 / 50 / 75 Klb</td>
</tr>
<tr>
<th scope="row">Output sensitivity</th>
<td>3.0 ± 0.008 mV/V</td>
</tr>
<tr>
<th scope="row">Input resistance</th>
<td>700 ± 7 Ω</td>
</tr>
<tr>
<th scope="row">Output resistance</th>
<td>703 ± 4 Ω</td>
</tr>
<tr>
<th scope="row">Insulation resistance</th>
<td>≥ 5,000 MΩ at 50 VDC</td>
</tr>
<tr>
<th scope="row">Zero balance</th>
<td>1.0% full scale</td>
</tr>
</tbody>
</table>
</div>
<div class="table-wrap">
<table>
<tbody>
<tr>
<th scope="row">Compensated temperature</th>
<td>-10 to +40°C</td>
</tr>
<tr>
<th scope="row">Operating temperature</th>
<td>-35 to +65°C</td>
</tr>
<tr>
<th scope="row">Recommended excitation</th>
<td>5 to 12 VDC</td>
</tr>
<tr>
<th scope="row">Maximum excitation</th>
<td>18 VDC</td>
</tr>
<tr>
<th scope="row">Safe overload</th>
<td>150% full scale</td>
</tr>
<tr>
<th scope="row">Ultimate overload</th>
<td>300% full scale</td>
</tr>
<tr>
<th scope="row">Cable</th>
<td>Shielded 4-conductor cable, Ø5 mm</td>
</tr>
<tr>
<th scope="row">Standard cable length</th>
<td>6 m</td>
</tr>
<tr>
<th scope="row">Datasheet marks</th>
<td>MC, FM approved, Ex NEPSI, IP67 and RoHS</td>
</tr>
</tbody>
</table>
</div>
</div>
<p class="note"><strong>Capacity note:</strong> The manufacturer datasheet lists 4 Klb in the technical capacity series; the supplied sale list specifies a 3,000 lb SKU instead. This page preserves the supplied purchasable models and reports the datasheet capacity series separately to avoid inventing a model or price.</p>
</section>
<section class="section" aria-labelledby="dimensions-heading">
<h2 id="dimensions-heading">Dimensions by capacity</h2>
<p class="section-intro">Dimensions are shown in millimeters, with inches in parentheses. Verify the selected model and mounting assembly before installation.</p>
<div class="table-wrap">
<table>
<thead>
<tr>
<th scope="col">Capacity (Klb)</th>
<th scope="col">L</th>
<th scope="col">L1</th>
<th scope="col">L2</th>
<th scope="col">ØD</th>
<th scope="col">Ød</th>
<th scope="col">H</th>
<th scope="col">W</th>
</tr>
</thead>
<tbody>
<tr>
<td>1–5</td>
<td>190.5 (7.5)</td>
<td>158.75 (6.25)</td>
<td>30.48 (1.2)</td>
<td>31.5 (1.24)</td>
<td>12.7 (0.5)</td>
<td>30.99 (1.22)</td>
<td>30.99 (1.22)</td>
</tr>
<tr>
<td>10–35</td>
<td>222.25 (8.75)</td>
<td>190.5 (7.5)</td>
<td>41.15 (1.62)</td>
<td>50.8 (2.0)</td>
<td>20.57 (0.81)</td>
<td>49.15 (1.94)</td>
<td>36.45 (1.44)</td>
</tr>
<tr>
<td>50–75</td>
<td>342.9 (13.5)</td>
<td>292.1 (11.5)</td>
<td>82.55 (3.25)</td>
<td>75.95 (2.99)</td>
<td>33.32 (1.31)</td>
<td>74.68 (2.94)</td>
<td>61.98 (2.44)</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="section" aria-labelledby="wiring-heading">
<h2 id="wiring-heading">B9D wiring</h2>
<div class="table-wrap">
<table>
<thead>
<tr>
<th scope="col">Signal</th>
<th scope="col">Wire color</th>
</tr>
</thead>
<tbody>
<tr>
<td>Input (+)</td>
<td>Red</td>
</tr>
<tr>
<td>Output (-)</td>
<td>White</td>
</tr>
<tr>
<td>Input (-)</td>
<td>Black</td>
</tr>
<tr>
<td>Output (+)</td>
<td>Green</td>
</tr>
</tbody>
</table>
</div>
<p class="fine-print">Always confirm wiring against the label and current manufacturer documentation before energizing or connecting the load cell.</p>
</section>
<section class="section" aria-labelledby="replacement-heading">
<h2 id="replacement-heading">Comparable load cells and replacement checks</h2>
<p class="answer"><strong>Short answer:</strong> the B9D may be a comparison candidate for the models below, but similarity does not guarantee direct interchangeability. Before replacing an existing sensor, compare rated capacity, dimensions, mounting pattern, load direction, output, excitation, wiring, sealing, approvals, cable length and calibration requirements.</p>
<ul class="comparison-list">
<li>Revere 9203</li>
<li>Celtron DSR-HSS</li>
<li>Sensortronics 65016W</li>
<li>Coti CI-16-SSW</li>
<li>Rice Lake RL75016SS</li>
</ul>
</section>
<section class="section faq" aria-labelledby="faq-heading">
<h2 id="faq-heading">Frequently asked questions</h2>
<details>
<summary>What is the Zemic B9D load cell used for?</summary>
<p>The B9D is designed for heavy-duty electronic weighing systems, including truck scales, vehicle testing facilities, track scales and tank scales. Its stainless steel, IP67 construction is suited to industrial environments where moisture, oil or corrosive media may be present.</p>
</details>
<details>
<summary>What capacities are available for the B9D?</summary>
<p>The supplied price list includes 1,000, 1,500, 2,000, 2,500, 3,000, 5,000, 10,000, 15,000, 20,000, 25,000, 35,000, 50,000 and 75,000 lb models. Select the capacity from the model menu to see its SKU and price.</p>
</details>
<details>
<summary>Is the B9D waterproof?</summary>
<p>The manufacturer datasheet identifies the B9D as IP67. This means the load cell enclosure is rated for dust protection and temporary immersion under the rating&#8217;s test conditions; it does not make the entire weighing installation waterproof. Junction boxes, connectors, and cable entries require suitable protection too.</p>
</details>
<details>
<summary>Is the B9D a direct replacement for a Revere 9203 or Rice Lake RL75016SS?</summary>
<p>It is a comparison candidate, not an automatically interchangeable replacement. A qualified scale professional should verify the mechanical, electrical, environmental, and metrological requirements for the exact capacity and installation before substitution.</p>
</details>
</section>
<section id="datasheet" class="section" aria-labelledby="datasheet-heading">Zemic B9D PDF datasheet</p>
<p class="section-intro">Review the original one-page manufacturer datasheet for specifications, approvals, outline dimensions and wiring details.</p>
<div class="pdf-shell">
<div class="pdf-toolbar"><strong>B9D.pdf · 1 page  </strong><a title="Zemic B9D PDF datasheet" href="https://loadcellexpress.com/wp-content/uploads/2026/08/B9D.pdf" target="_blank" rel="noopener">Open PDF in a new tab</a></div>
</div>
</section>
<p class="fine-print">Technical data is transcribed from the supplied Zemic B9D datasheet for product selection and engineering review. Confirm the current datasheet, exact accuracy class, approvals and application requirements before ordering or installation.</p>
<p>&nbsp;</p>